Abstract

Limited availability of Western scientific equipment, explains a growing need to switch to using scientific instruments made in China. This is especially true in the case of optical biosensors operating on the surface plasmon resonance (SPR) effect. However, comparability of experimental data obtained using Western and Chinese biosensors has not been investigated yet. In this work we have comparedresults of SPR analysis of the kinetics and affinity of interaction of IgG2a and IgG1 antibodies with protein A. Two biosensos Biacore X-100 (“Cytiva”, USA) and MI-S200D (“Inter-Bio”, China) have been used. It was shown that the values of the association rate constants obtained on both devices for two antibodies were close within one order of magnitude. For IgG1 antibodies, the dissociation rate constants were almost identical. Both devices provide high-quality data that are well described by a simple 1:1 model (Langmuir binding).

Article Details

How to Cite
Gnedenko, O., Mezentsev, Y., Yablokov, E., Kaluzhskiy, L., Ershov, P., Gilep, A., & Ivanov, A. (2025). Comparison of the Results of SPR Analysis of Antigen-antibody Interactions Performed Using Optical Biosensors Biacore X-100 (“Cytiva”, USA) and MI-S200D (“Inter-Bio”, China). Biomedical Chemistry: Research and Methods, 7(4), e00246. https://doi.org/10.18097/BMCRM00246
Section
EXPERIMENTAL RESEARCH

References

  1. Myszka, D.G. (2000) Kinetic, equilibrium, and thermodynamic analysis of macromolecular interactions with BIACORE. В Methods in Enzymology (Т. 323, pp. 325–340). Elsevier. DOI
  2. Gnedenko, O.V., Mezentsev, Y.V., Molnar, A.A., Lisitsa, A.V., Ivanov, A.S., Archakov, A.I. (2013) Highly sensitive detection of human cardiac myoglobin using a reverse sandwich immunoassay with a gold nanoparticle-enhanced surface plasmon resonance biosensor. Analytica Chimica Acta, 759, 105–109. DOI
  3. Davidoff, S.N., Ditto, N.T., Brooks, A.E., Eckman, J., Brooks, B.D. (2015) Surface plasmon resonance for therapeutic antibody characterization. Fang, В.Y.(Ред.), Label-Free Biosensor Methods in Drug Discovery (pp. 35–76). New York, NY: Springer New York. DOI
  4. Regenmortel, M.H.V.V., Altschuh, D., Chatellier, J., Christensen, L., Rauffer-Bruyère, N., Richalet-Secordel, P., Witz, J., Zeder-Lutz, G. (1998) Measurement of antigen–antibody interactions with biosensors. Journal of Molecular Recognition, 11(1–6), 163–167. DOI
  5. Myszka, D.G. (1997) Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors. Current Opinion in Biotechnology, 8(1), 50–57. DOI
  6. McDonnell, J.M. (2001) Surface plasmon resonance: towards an understanding of the mechanisms of biological molecular recognition. Current Opinion in Chemical Biology, 5(5), 572–577. DOI
  7. Cooper, M.A. (2002) Optical biosensors in drug discovery. Nature Reviews Drug Discovery, 1(7), 515–528. DOI
  8. Knowling, S., Clark, J., Sjuts, H., Abdiche, Y.N. (2020) Direct comparison of label-free biosensor binding kinetics obtained on the Biacore 8K and the Carterra LSA. SLAS Discovery, 25(9), 977–984. DOI
  9. Yang, D., Singh, A., Wu, H., Kroe-Barrett, R. (2016) Comparison of biosensor platforms in the evaluation of high affinity antibody-antigen binding kinetics. Analytical Biochemistry, 508, 78–96. DOI
  10. Bright, R.A., Carter, D.M., Crevar, C.J., Toapanta, F.R., Steckbeck, J.D., Cole, K.S., Kumar, N.M., Pushko, P., Smith, G., Tumpey, T.M., Ross, T.M. (2008) Cross-Clade Protective Immune Responses to Influenza Viruses with H5N1 HA and NA Elicited by an Influenza Virus-Like Particle. PLoS ONE, 3(1), e1501. DOI
  11. Fägerstam, L.G., Frostell-Karlsson, Å., Karlsson, R., Persson, B., Rönnberg, I. (1992) Biospecific interaction analysis using surface plasmon resonance detection applied to kinetic, binding site and concentration analysis. Journal of Chromatography A, 597(1–2), 397–410. DOI
  12. Schuck, P. (1997) Use of surface plasmon resonance to probe the equilibrium and dynamic aspects of interactions between biological macromolecules. Annual Review of Biophysics and Biomolecular Structure, 26, 541–566. DOI
  13. Hober, S., Nord, K., Linhult, M. (2007) Protein A chromatography for antibody purification. Journal of Chromatography B, 848(1), 40–47. DOI